- Home
- Concrete Test Report Report ID: 61204
- Edit Download Report
Concrete Test Report
Date :08/30/2023
Project No :2023C159
Client Company :CW Matthews
Arrival Time :08/30/2023 7:30
Onsite Hours :06:00
Name of the Project :Airfield Repairs 2021-23
Project Location :HJAIA, Atlanta, GA
Weather :cloudy
Departure Time :08/30/2023 13:30
ASEC Technician Name :Aminullah Azimi
Concrete Placement Information
Location(S):
N/A
Testing:
A Set of concrete specimens (6 per set) were cast during the cast-in-place concrete pour at the above referenced location, in accordance with ASTM C31. The specimen will remain on site for the initial 24-48 hrs curing.
Compliance:
Field placement of concrete appeared to be in accordance with the project specifications (i.e., slump, temperature, etc) (refer to remarks below)
Deviations and/or noncompliances were noted during the field placement (refer to remarks below)
Specimen
Pick Up: A Sets of concrete specimens/ 6 specimen per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Pick Up: A Sets of concrete specimens/ 6 specimen per set were picked up & transported to AS Engineering and Consulting LLC (ASEC) for curing and testing in accordance with ASTM C39, C670/1231
Field Curing:
Specimen were stored for the initial 24 hours.
Near the poured structure
In an insulated curing box
Other
Remarks:
Field Test Data
Set Number :A
Date Sampled :08/30/2023
Sampled By :Aminullah Azimi
Contractor :Technique concrete constriction
Truck Number :2089
Time Batched :9:33
Location of Placement :Ramp 6 Nin the front of E116
Number of samples cast :6
Ambient Temperature (°f) :76
Slump (in.) :7
Water added (gal.) :N/A
Laboratory Number :A
Time Sampled :10:20
Weather Condition :cloudy
Concrete Supplier :Argos
Mix ID :50CAX225
Quantity of Load (cu. yd.) :3
Sample Cast :A
Specified Strength :5000
Concrete Temperature(°f) :81
Air Content (%) :4.6
Unit Weight (pcf) :N/A
Strength Test Results
| Specimen Number | Scheduled Test Date | Date Tested | Age (days) | Dia(in.) | Area (sq in.) | Maximum Loads (lbf) | Strength (lbs) | % Design Strength | Type of Fracture |
|---|---|---|---|---|---|---|---|---|---|
| A | 08/31/2023 | 08/31/2023 | 1 | 6 | 18.26 | 0 | 0.0 |
UNLESS OTHERWISE SPECIFIED, TESTS WERE PERFORMED IN ACCORDANCE WITH ASTM TEST METHODS C31, C39, C138, C143, C173, AND C1064. FRACTURE TYPE INDICATED BY NUMBER.
(Type 1) Cone (Type 2) Cone-split (Type 3) Vertical (Type 4) Shear (Type 5) Edge Fracture (Type 6) Pointed
Technician Signature / DateAminullah Azimi, August 30, 2023
Reviewer Name / DateRamchandra Mogulla, September 05, 2023