Density Test Report
Date :05/29/2024
Project No :2024C116
Client Company :Peeples Owner, LLC
Arrival Time :05/29/2024
Onsite Hours :
Name of the Project :Peeples Valley Rd, Overlook at Pettit
Project Location :Cartersville
Weather :sunny
Departure Time :05/29/2024
ASEC Technician Name :Russell Hendrix
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 05/28/2024 | 1 | 16.2 | 125.0 | P-01 | 108.9 | 17.9 | 98.8 | 95 | D6938 | Pass |
| Location : | Section 1 south side, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 05/28/2024 | 2 | 17.8 | 105.7 | P-01 | 108.9 | 17.9 | 97.1 | 95 | D6938 | Pass |
| Location : | Section 1 west side, Elv/Depth :Finished grade | |||||||||
| Comment : | Also, this area was proof-rolled | Gauge Serial No. :30942 | ||||||||
Technician Signature / DateRussell Hendrix, May 29, 2024
Reviewer Name / DateKenneth Mosman, July 15, 2024