- Home
- Density Test Report Report ID: 70816
- This project is inactive from admin. Download Report
Density Test Report
Date :10/02/2024
Project No :2021C002
Client Company :CW Matthews
Arrival Time :10/02/2024 07:00
Onsite Hours :9:00
Name of the Project :Runway 9L End Around Taxiway
Project Location :HJAIA
Weather :Cloudy
Departure Time :10/02/2024 16:00
ASEC Technician Name :Fawad Shagiwal
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 10/02/2024 | 1 | 6.5 | 119.1 | 13 | 125.1 | 11.6 | 95.2 | 95 | D6938 | Pass |
| Location : | Runway 9L End Around Taxiway, Elv/Depth :1.2 feet below finished grade. | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 10/02/2024 | 2 | 3.6 | 116.0 | 13 | 125.1 | 11.6 | 92.7 | 95 | D6938 | Fail |
| Location : | Runway 9L End Around Taxiway, Elv/Depth :1.2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
Technician Signature / DateFawad Shagiwal, October 2, 2024
Reviewer Name / DateKenneth Mosman, October 23, 2024