- Home
- Density Test Report Report ID: 71449
- This project is inactive from admin. Download Report
Density Test Report
Date :10/16/2024
Project No :2024C168
Client Company :CCG
Arrival Time :10/16/2024 11:00
Onsite Hours :07:30
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :sunny
Departure Time :10/16/2024 18:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 10/16/2024 | 187 | 19.1 | 88.6 | 26082 | 94.1 | 24.3 | 94.2 | 98 | D2937 | Fail |
| Location : | Sewer trench, 50 feet NE from MHSA8, Elv/Depth :finished grade | |||||||||
| Comment : | Recommend recompaction and retesting to the contractor who elected not to do so. | |||||||||
| 10/16/2024 | 188 | 23.7 | 84.4 | 26082 | 94.1 | 24.3 | 89.7 | 98 | D2937 | Fail |
| Location : | Sewer trench, 10 feet SE from MHSB1, Elv/Depth :finished grade | |||||||||
| Comment : | Recommend recompaction and retesting to the contractor who elected not to do so. | |||||||||
| 10/16/2024 | 189 | 20.2 | 90.2 | 26082 | 94.1 | 24.3 | 95.9 | 98 | D2937 | Fail |
| Location : | Sewer trench, 29 feet NW from MHSB1, Elv/Depth :finished grade | |||||||||
| Comment : | ||||||||||
| 10/16/2024 | 190 | 23.2 | 89.6 | 26082 | 94.1 | 24.3 | 95.2 | 95 | D2937 | Pass |
| Location : | Sewer trench, 110 feet NW from MHSB1, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | ||||||||||
| 10/16/2024 | 191 | 22.0 | 92.2 | 26082 | 94.1 | 24.3 | 98.0 | 95 | D2937 | Pass |
| Location : | Sewer trench, 13 feet SE from MHSB2, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 10/16/2024 | 192 | 20.3 | 90.8 | 26082 | 94.1 | 24.3 | 96.5 | 95 | D2937 | Pass |
| Location : | Sewer trench, 10 feet NW from MHSB2, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 10/16/2024 | 193 | 22.9 | 89.6 | 26082 | 94.1 | 24.3 | 95.2 | 95 | D2937 | Pass |
| Location : | Sewer trench, 21 feet SE from MHSB3, Elv/Depth :2.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
Technician Signature / DateAminullah Azimi, October 16, 2024
Reviewer Name / DateKenneth Mosman, October 20, 2024