- Home
- Density Test Report Report ID: 71481
- Edit Download Report
Density Test Report
Date :10/18/2024
Project No :2024C202
Client Company :CCG
Arrival Time :10/18/2024 08:00
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :
Departure Time :10/18/2024
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 10/18/2024 | 2 | 21.9 | 96.9 | S-01 | 101.9 | 20.5 | 95.1 | 95 | D6938 | Pass |
| Location : | Adjacent road near Lot #89, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
Technician Signature / DateSolomon Cherie, October 18, 2024
Reviewer Name / DateKenneth Mosman, January 09, 2025