Skip to content

Density Test Report

Date :10/18/2024
Project No :2023C201
Client Company :Artisan Built Communities
Arrival Time :10/18/2024 08:30
Onsite Hours :9:00
Name of the Project :Jasons Walk - Era Drive
Project Location :Era Drive, Cumming, GA
Weather :Sunny
Departure Time :10/18/2024 17:30
ASEC Technician Name :Fawad Shagiwal

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/18/2024 1 19.3 103.5 24504 101.6 20.6 101.9 98 D6938 Pass
Location : Lot #30, Elv/Depth :at finished grade
Comment : Gauge Serial No. :29588
10/18/2024 2 17.2 121.9 24504 101.6 20.6 102.4 98 D6938 Pass
Location : Lot #30, Elv/Depth :at finished grade
Comment : Gauge Serial No. :29588
10/18/2024 3 19.1 123.0 24504 101.6 20.6 101.7 98 D6938 Pass
Location : Lot #30, Elv/Depth :at finished grade
Comment : Gauge Serial No. :29588
Technician Signature / DateFawad Shagiwal, October 18, 2024
Reviewer Name / DateKenneth Mosman, February 01, 2025