Density Test Report
Date :10/21/2024
Project No :2024C202
Client Company :CCG
Arrival Time :10/21/2024 07:45
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :
Departure Time :10/21/2024
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 10/21/2024 | 1 | 20.9 | 103.8 | S-01 | 101.9 | 20.5 | 101.9 | 95 | D6938 | Pass |
| Location : | Lot #88, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 10/21/2024 | 2 | 24.3 | 97.7 | S-01 | 101.9 | 20.5 | 95.9 | 95 | D6938 | Pass |
| Location : | Entranceway, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 10/21/2024 | 3 | 24.8 | 95.0 | S-02 | 97.2 | 24.9 | 97.7 | 95 | D6938 | Pass |
| Location : | Lot #89, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 10/21/2024 | 4 | 28.4 | 89.7 | S-02 | 97.2 | 24.9 | 92.3 | 95 | D6938 | Fail |
| Location : | Lot #88, Elv/Depth :2.5 feet below | |||||||||
| Comment : | Failed compaction result due to excessive in place moisture content (above 3 percent over optimum moisture). Scarify, aerate and recompact. | Gauge Serial No. :30942 | ||||||||
| 10/21/2024 | 5 | 24.1 | 93.8 | S-02 | 97.2 | 24.9 | 96.5 | 95 | D6938 | Pass |
| Location : | Lot #89, Elv/Depth :6 inches below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
Technician Signature / DateSolomon Cherie, October 21, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025