Skip to content

Density Test Report

Date :10/22/2024
Project No :2024C116
Client Company :Peeples Owner, LLC
Arrival Time :10/22/2024 08:30
Onsite Hours :08:30
Name of the Project :Peeples Valley Rd, Overlook at Pettit
Project Location :Cartersville
Weather :Sunny
Departure Time :10/22/2024 17:00
ASEC Technician Name :Fawad Shagiwal

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/22/2024 1 17.3 103.7 P-01 108.9 17.9 95.2 95 D6938 Pass
Location : Sewer line trench, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :29588
10/22/2024 2 17.0 106.6 P-01 108.9 17.9 97.9 95 D6938 Pass
Location : Sewer line trench, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :29588
10/22/2024 3 18.4 107.6 P-01 108.9 17.9 98.8 95 D6938 Pass
Location : Sewer line trench, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :29588
10/22/2024 4 17.6 102.1 P-02 107.4 20.2 95.1 95 D6938 Pass
Location : Sewer line trench, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :29588
Technician Signature / DateFawad Shagiwal, October 22, 2024
Reviewer Name / DateKenneth Mosman, February 02, 2025