Skip to content

Density Test Report

Date :10/11/2024
Project No :2024C237
Client Company :SR Homes
Arrival Time :10/11/2024 8:00
Onsite Hours :05:30
Name of the Project :Stonewood PH 4, Stone Road
Project Location :Watkinsville
Weather :sunny
Departure Time :10/11/2024 13:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/11/2024 1 22 98.0 S-01 101.2 18.6 96.8 95 D6938 Pass
Location : roadway circle (location shown in pictures), Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :85759
10/11/2024 2 22 96.2 S-01 101.2 18.6 95.1 95 D6938 Pass
Location : roadway circle (location shown in the pictures), Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :85759
10/11/2024 3 23.4 99.7 S-01 101.2 18.6 98.5 95 D6938 Pass
Location : roadway circle (location shown in the pictures), Elv/Depth :5 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, October 11, 2024
Reviewer Name / DateKenneth Mosman, January 12, 2025