Our AS Engineering & Consulting (ASEC) representative arrived on site to observe field activities. The following tasks were performed:
Observed the placement of fill/grading for Lots #104, #105 and #106 today. Compaction tests were performed using a nuclear density gauge. Overall, the results of density testing confirmed that fill compaction met the project and ASTM requirements. Results are attached in separate reports.
The compaction test today for Lot #119 (Test 5) was a retest for the failing compaction test from yesterday (November 12). [now passes]
Please contact us if you have any questions regarding this report or of the density test results.

Picture showing Lot#106 at sugrade

Picture showing Lot#104 at sugrade