Skip to content

Density Test Report

Date :11/22/2024
Project No :2024C202
Client Company :CCG
Arrival Time :11/22/2024 07:15
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Sunny
Departure Time :
ASEC Technician Name :Solomon Cherie

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/22/2024 1 30.2 88.8 S-02 97.2 24.9 91.4 95 D6938 Fail
Location : Lot #74, Elv/Depth :4.5 feet below finished grade
Comment : In place moisture contents much higher than optimum. Recommend scarifying, aerating and recompaction. Gauge Serial No. :30942
11/22/2024 2 29.4 86.3 S-02 97.2 24.9 88.8 95 D6938 Fail
Location : Lot #73, Elv/Depth :5 feet below finished grade
Comment : In place moisture contents much higher than optimum. Recommend scarifying, aerating and recompaction. Gauge Serial No. :30942
11/22/2024 3 27.9 92.4 S-02 97.2 24.9 95.1 95 D6938 Pass
Location : Lot #111, Elv/Depth :7 feet below finished grade
Comment : These soils were obtained from a cut area and found to have moisture contents closer to optimum Gauge Serial No. :30942
Technician Signature / DateSolomon Cherie, November 22, 2024
Reviewer Name / DateKenneth Mosman, January 09, 2025