Skip to content

Density Test Report

Date :11/26/2024
Project No :2024C202
Client Company :CCG
Arrival Time :11/26/2024 10:45
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Cloudy
Departure Time :11/26/2024
ASEC Technician Name :Solomon Cherie

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
11/26/2024 1 28.6 87.2 S-02 97.2 24.9 89.7 95 D6938 Fail
Location : Lot #73, Elv/Depth :5 feet below finished grade
Comment : In place moisture contents more than 3 percent over optimum. Scarifying, aerating and recompaction required. Gauge Serial No. :30942
11/26/2024 2 31.7 108.8 S-02 97.2 24.9 85.0 95 D6938 Fail
Location : Access road, Elv/Depth :3 feet below finished grade
Comment : In place moisture contents more than 3 percent over optimum. Scarifying, aerating and recompaction required. Gauge Serial No. :30942
Technician Signature / DateSolomon Cherie, November 26, 2024
Reviewer Name / DateKenneth Mosman, January 10, 2025