- Density Test Report Report ID: 74199
- This project is inactive from admin. Download Report
Density Test Report
Date :12/07/2024
Project No :2024C168
Client Company :CCG
Arrival Time :12/07/2024 8:15
Onsite Hours :07:15
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson
Weather :cloudy
Departure Time :12/07/2024 15:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 12/07/2024 | 361 | 21.9 | 99.8 | 26081 | 102.9 | 20.0 | 97.0 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #197, Elv/Depth :0.5 foot below finished grade | |||||||||
| Comment : | ||||||||||
| 12/07/2024 | 362 | 24.5 | 98.3 | 26081 | 102.9 | 20.0 | 95.5 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #196, Elv/Depth :0.5 feet below finished grade | |||||||||
| Comment : | ||||||||||
| 12/07/2024 | 363 | 21.3 | 100.3 | 26081 | 102.9 | 20.0 | 97.5 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #194, Elv/Depth :0.5 foot below finished grade | |||||||||
| Comment : | ||||||||||
| 12/07/2024 | 364 | 18.8 | 97.6 | 26086 | 99.8 | 19.7 | 97.8 | 95 | D6938 | Pass |
| Location : | retaining wall at Station 60+00, Elv/Depth :7 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :8579 | |||||||||
| 12/07/2024 | 366 | 16.5 | 97.4 | 26086 | 99.8 | 19.7 | 97.6 | 95 | D6938 | Pass |
| Location : | retaining wall #2 backfill at Station 100+00, Elv/Depth :6 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 12/07/2024 | 366 | 18.3 | 98.6 | 26086 | 99.8 | 19.7 | 98.8 | 95 | D6938 | Pass |
| Location : | retaining wall #2 backfill at Station 20+00, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 12/07/2024 | 367 | 22.4 | 98.6 | 26081 | 102.9 | 20.0 | 95.8 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #220, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | ||||||||||
| 12/07/2024 | 368 | 21.2 | 99.1 | 26081 | 102.9 | 20.0 | 96.3 | 95 | D2937 | Pass |
| Location : | water line in front of Lot #215, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | ||||||||||
Technician Signature / DateAminullah Azimi, December 7, 2024
Reviewer Name / DateKenneth Mosman, January 11, 2025