- Home
- Density Test Report Report ID: 74403
- Edit Download Report
Density Test Report
Date :12/17/2024
Project No :2024C202
Client Company :CCG
Arrival Time :12/17/2024 07:30
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Cloudy
Departure Time :
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 12/17/2024 | 1 | 27.5 | 92.0 | S-02 | 97.2 | 24.9 | 94.7 | 95 | D6938 | Fail |
| Location : | Lot #114, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | This test deemed satisfactory following a short proof-roll that found the area stable. | Gauge Serial No. :30942 | ||||||||
| 12/17/2024 | 2 | 26.1 | 95.7 | S-02 | 97.2 | 24.9 | 98.5 | 95 | D6938 | Pass |
| Location : | Lot #115, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 12/17/2024 | 3 | 27.4 | 92.5 | S-02 | 97.2 | 24.9 | 95.2 | 95 | D6938 | Pass |
| Location : | Lot #114, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
Technician Signature / DateSolomon Cherie, December 17, 2024
Reviewer Name / DateKenneth Mosman, January 10, 2025