Density Test Report

Date :01/08/2025
Project No :2024C202
Client Company :CCG
Arrival Time :01/08/2025 07:30
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Sunny
Departure Time :
ASEC Technician Name :Solomon Cherie

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/08/2025 1 23.7 87.1 S-02 97.2 24.9 89.6 95 D6938 Fail
Location : Lot #29, Elv/Depth :12 feet below finished grade
Comment : Compaction test failure. Recommended to scarify and recompact prior to retesting. Gauge Serial No. :30942
01/08/2025 2 24.4 92.8 S-02 97.2 24.9 95.5 95 D6938 Pass
Location : Lot #30, Elv/Depth :11 feet below finished grade
Comment : Gauge Serial No. :30942
Technician Signature / DateSolomon Cherie, January 8, 2025
Reviewer Name / DateKenneth Mosman, January 10, 2025