Skip to content

Density Test Report

Date :01/14/2025
Project No :2024C202
Client Company :CCG
Arrival Time :01/14/2025 07:30
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Clear sky and sunny
Departure Time :01/14/2025
ASEC Technician Name :Solomon Cherie

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/14/2025 1 26.1 90.9 S-02 97.2 24.9 93.5 95 D6938 Fail
Location : Lot #30, Elv/Depth :10 feet below finished grade
Comment : Recompaction required prior to retesting this area. Contractor notified. Gauge Serial No. :30942
01/14/2025 2 26.2 90.7 S-02 97.2 24.9 93.3 95 D6938 Fail
Location : Lot #28, Elv/Depth :14 feet below finished grade
Comment : Recompaction required prior to retesting this area. Contractor notified. Gauge Serial No. :30942
01/14/2025 3 26.1 91.9 S-02 97.2 24.9 94.5 95 D6938 Fail
Location : Lot #30, Elv/Depth :9 feet below finished grade
Comment : Retest in general area of Test #1. Compaction improved. Gauge Serial No. :30942
01/14/2025 4 28.3 84.7 S-02 97.2 24.9 87.1 95 D6938 Fail
Location : Lot #29, Elv/Depth :12 feet below finished grade
Comment : In place moisture content excessively higher than optimum moisture content. Recommended scarification, aeration and recompaction. Gauge Serial No. :30942
Technician Signature / DateSolomon Cherie, January 14, 2025
Reviewer Name / DateKenneth Mosman, January 15, 2025