Skip to content

Density Test Report

Date :01/24/2025
Project No :2024C202
Client Company :CCG
Arrival Time :01/24/2025 07:30
Onsite Hours :
Name of the Project :Old Griffin Rd - Hawthorne Reserve
Project Location :Dallas
Weather :Partly cloudy
Departure Time :01/24/2025
ASEC Technician Name :Solomon Cherie

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/24/2025 1 26.9 116.8 S-02 97.2 24.9 94.7 95 D6938 Fail
Location : Lot #27, Elv/Depth :3.5 feet below finished grade
Comment : Recompaction recommended in this area prior to further fill placement. Gauge Serial No. :30942
01/24/2025 2 28.5 116.9 S-02 97.2 24.9 93.6 95 D6938 Fail
Location : Lot #29, Elv/Depth :2.5 feet below finished grade
Comment : Recompaction recommended in this area prior to further fill placement. Gauge Serial No. :30942
01/24/2025 3 27.5 117.9 S-02 97.2 24.9 95.2 95 D6938 Pass
Location : Lot #27, Elv/Depth :3.5 feet below finished grade
Comment : Some minor pumping/deflection during proof-rolling of this area indicating that some moisture contents may still be high. Gauge Serial No. :30942
Technician Signature / DateSolomon Cherie, January 24, 2025
Reviewer Name / DateKenneth Mosman, January 26, 2025