Skip to content

Density Test Report

Date :01/28/2025
Project No :2024C168
Client Company :Century Communities
Arrival Time :01/28/2025 8:00
Onsite Hours :9:00
Name of the Project :Reserve @ Gum Springs
Project Location :Jefferson, Jackson County, Georgia
Weather :sunny
Departure Time :01/28/2025 17:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/28/2025 477 5 136.2 27651 143.6 5.4 94.8 92 D6938 Pass
Location : Retaining wall #2, at Station 0+16, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
01/28/2025 478 4.2 141.2 27651 143.6 5.4 98.3 92 D6938 Pass
Location : Retaining wall #2 at Station 0+45, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
01/28/2025 479 5.3 137.1 27651 143.6 5.4 95.5 92 D6938 Pass
Location : Backfill for retaining wall #2, at Station 1+10, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
01/28/2025 480 3.7 140.4 27651 143.6 5.4 97.8 92 D6938 Pass
Location : Retaining wall #2 at Station 0+90, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
01/28/2025 481 4.4 137.8 27651 143.6 5.4 96.0 92 D6938 Pass
Location : Retaining wall #2, at Station 0+40, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, January 28, 2025
Reviewer Name / DateKenneth Mosman, February 01, 2025