Skip to content

Density Test Report

Date :04/09/2025
Project No :2025C150
Client Company :Davidson Homes
Arrival Time :04/09/2025 08:00
Onsite Hours :9:00
Name of the Project :Riverwood Retaining Wall
Project Location :Dallas
Weather :sunny
Departure Time :04/09/2025 17:00
ASEC Technician Name :Vamsi Polisetty

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/09/2025 1 28.2 109.6 2025-009 SP 89.2 25.2 95.9 95 D6938 Pass
Location : Lot #229 (next to Lot #228), Elv/Depth :first lift
Comment : Gauge Serial No. :29588
04/09/2025 2 29.5 86.6 2025-009 SP 89.2 25.2 97.1 95 D6938 Pass
Location : Lot #228 (random station next to Lot #227), Elv/Depth :first lift
Comment : In-situ moisture contents well above optimum moisture contents. Gauge Serial No. :29588
04/09/2025 3 28.3 90.3 2025-009 SP 89.2 25.2 101.2 95 D6938 Pass
Location : Lot #228 (random station next to Lot #227), Elv/Depth :first lift
Comment : Gauge Serial No. :29588
04/09/2025 4 24.3 112.4 2025-009 SP 89.2 25.2 101.3 95 D6938 Pass
Location : Lot #227 (random station next to Lot #226), Elv/Depth :first lift
Comment : Gauge Serial No. :29588
04/09/2025 5 26.8 92.0 2025-009 SP 89.2 25.2 103.1 95 D6938 Pass
Location : Lot #227 (random station next to Lot #226), Elv/Depth :first lift
Comment : Gauge Serial No. :29588
04/09/2025 6 31.7 88.2 2025-009 SP 89.2 25.2 98.9 95 D6938 Pass
Location : Lot #226 (random station next to Lot #225), Elv/Depth :first lift
Comment : In-situ moisture contents well above optimum moisture. Gauge Serial No. :29588
04/09/2025 7 24.9 92.6 2025-009 SP 89.2 25.2 103.8 95 D6938 Pass
Location : Lot #225 (random station in Lot #225), Elv/Depth :first lift
Comment : Gauge Serial No. :29588
Technician Signature / DateVamsi Polisetty, April 9, 2025
Reviewer Name / DateKenneth Mosman, May 02, 2025