- Home
- Density Test Report Report ID: 79915
- This project is inactive from admin. Download Report
Density Test Report
Date :04/10/2025
Project No :2025C150
Client Company :Davidson Homes
Arrival Time :04/10/2025 08:30
Onsite Hours :08:30
Name of the Project :Riverwood Retaining Wall
Project Location :Dallas
Weather :sunny
Departure Time :04/10/2025 17:00
ASEC Technician Name :Vamsi Polisetty
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/10/2025 | 1 | 29.6 | 88.0 | 2025-009 SP | 89.2 | 25.2 | 98.7 | 95 | D6938 | Pass |
| Location : | Lot #229 (random station next to Lot #228), Elv/Depth :third lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/10/2025 | 2 | 19.9 | 122.5 | 2025-015 SP | 102.8 | 18.1 | 99.4 | 95 | D6938 | Pass |
| Location : | Lot #228, Elv/Depth :third lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/10/2025 | 3 | 29.4 | 86.8 | 2025-009 SP | 89.2 | 25.2 | 97.3 | 95 | D6938 | Pass |
| Location : | Lot #228 (random station next to Lot #227), Elv/Depth :third lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/10/2025 | 4 | 27.2 | 89.4 | 2025-009 SP | 89.2 | 25.2 | 100.2 | 95 | D6938 | Pass |
| Location : | Lot #227, Elv/Depth :third lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/10/2025 | 5 | 28.1 | 88.6 | 2025-009 SP | 89.2 | 25.2 | 99.3 | 95 | D6938 | Pass |
| Location : | Lot #227 (random station next to Lot #226), Elv/Depth :third lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/10/2025 | 6 | 26.9 | 87.6 | 2025-009 SP | 89.2 | 25.2 | 98.2 | 95 | D6938 | Pass |
| Location : | Lot #227, Elv/Depth :third lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/10/2025 | 7 | 26.5 | 111.7 | 2025-009 SP | 89.2 | 25.2 | 99.0 | 95 | D6938 | Pass |
| Location : | Lot #226, Elv/Depth :third lift | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 04/10/2025 | 8 | 29.1 | 83.0 | 2025-009 SP | 89.2 | 25.2 | 93.0 | 95 | D6938 | Fail |
| Location : | Lot #225 (random station in Lot #225), Elv/Depth :third lift | |||||||||
| Comment : | Moisture content well above optimum moisture. Recommended scarify, aerate and recompact. | Gauge Serial No. :29588 | ||||||||
Technician Signature / DateVamsi Polisetty, April 10, 2025
Reviewer Name / DateKenneth Mosman, May 02, 2025