- Home
- Density Test Report Report ID: 80004
- Edit Download Report
Density Test Report
Date :04/16/2025
Project No :2025C146
Client Company :Davidson Homes, LLC
Arrival Time :04/16/2025 08:00
Onsite Hours :07:30
Name of the Project :Greene Farms Subdivision
Project Location :1451 Highway 113, Cartersville, Georgia
Weather :Sunny
Departure Time :04/16/2025 15:30
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/16/2025 | 1 | 19.2 | 105.7 | ASECP003 | 109.2 | 18.5 | 96.8 | 95 | D6938 | Pass |
| Location : | Roadway sta. 12+00, Elv/Depth :9 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 04/16/2025 | 2 | 18.5 | 105.3 | ASECP003 | 109.2 | 18.5 | 96.4 | 95 | D6938 | Pass |
| Location : | Roadway sta. 12+75, Elv/Depth :9.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 04/16/2025 | 3 | 19.3 | 105.5 | ASECP003 | 109.2 | 18.5 | 96.6 | 95 | D6938 | Pass |
| Location : | Roadway sta.13+65, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 04/16/2025 | 4 | 17.7 | 107.2 | ASECP003 | 109.2 | 18.5 | 98.2 | 95 | D6938 | Pass |
| Location : | Roadway sta.14+10, Elv/Depth :10.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 04/16/2025 | 5 | 18.1 | 107.4 | ASECP003 | 109.2 | 18.5 | 98.4 | 95 | D6938 | Pass |
| Location : | Roadway sta.15+00, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 04/16/2025 | 6 | 22.6 | 104.5 | ASECP003 | 109.2 | 18.5 | 95.7 | 95 | D6938 | Pass |
| Location : | Roadway 16+25, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 04/16/2025 | 7 | 21.6 | 103.2 | ASECP003 | 109.2 | 18.5 | 94.5 | 95 | D6938 | Fail |
| Location : | Lot #30, Elv/Depth :9 feet below finished grade | |||||||||
| Comment : | Contractor informed that recompaction in this area was required. | Gauge Serial No. :38069 | ||||||||
| 04/16/2025 | 8 | 21.6 | 105.4 | ASECP003 | 109.2 | 18.5 | 96.5 | 95 | D6938 | Pass |
| Location : | Lot # 31, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
Technician Signature / DateClyde Smith, April 16, 2025
Reviewer Name / DateKenneth Mosman, May 03, 2025