Date :04/14/2025
Project No :2024C213
Client Company :WDG
Arrival Time :04/14/2025 8:00
Onsite Hours :9:30
Name of the Project :Covington Town Center PH II
Project Location :Covington, GA
Weather :cloudy
Departure Time :04/14/2025 17:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/14/2025 | 1 | 18.5 | 123.4 | ASECP001 | 106.0 | 18.2 | 98.2 | 95 | D6938 | Pass |
| Location : | sewer trench, 62 feet East from existing MH, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/14/2025 | 2 | 17.9 | 103.6 | ASECP001 | 106.0 | 18.2 | 97.7 | 95 | D6938 | Pass |
| Location : | sewer trench, 19 feet SE from MHB2, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/14/2025 | 3 | 17.9 | 104.6 | ASECP001 | 106.0 | 18.2 | 98.7 | 95 | D6938 | Pass |
| Location : | water storm trench, 23 feet East from MHB2, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/14/2025 | 4 | 18.2 | 102.9 | ASECP001 | 106.0 | 18.2 | 97.1 | 95 | D6938 | Pass |
| Location : | water storm trench, 19 feet west from MHB3, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/14/2025 | 5 | 15.7 | 103.0 | ASECP001 | 106.0 | 18.2 | 97.2 | 95 | D6938 | Pass |
| Location : | water storm trench, between MHB3 and MHB4., Elv/Depth :2.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/14/2025 | 6 | 17.2 | 104.2 | ASECP001 | 106.0 | 18.2 | 98.3 | 95 | D6938 | Pass |
| Location : | water storm trench, 15 feet south from MHB1, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :857589 | |||||||||
| 04/14/2025 | 7 | 17.9 | 103.8 | ASECP001 | 106.0 | 18.2 | 97.9 | 95 | D6938 | Pass |
| Location : | water storm trench, 15 feet north from MHA0, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/14/2025 | 8 | 17.9 | 104.2 | ASECP001 | 106.0 | 18.2 | 98.3 | 95 | D6938 | Pass |
| Location : | water storm trench, between MHA2 and MHA3, Elv/Depth :1.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
Technician Signature / DateAminullah Azimi, April 14, 2025