Skip to content

Density Test Report

Date :04/15/2025
Project No :2024C213
Client Company :WDG
Arrival Time :04/15/2025 8:00
Onsite Hours :10:00
Name of the Project :Covington Town Center PH II
Project Location :Covington, GA
Weather :sunny
Departure Time :04/15/2025 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/15/2025 1 16.5 103.8 ASECP001 106.0 18.2 97.9 95 D6938 Pass
Location : water storm trench, between existing MH and MHC1, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :85759
04/15/2025 2 17.5 122.5 ASECP001 106.0 18.2 98.4 95 D6938 Pass
Location : water storm trench, 33 feet East from MHC1, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :85759
04/15/2025 3 15.9 104.3 ASECP001 106.0 18.2 98.4 95 D6938 Pass
Location : water storm trench, 53 feet West from MHD1, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :85759
04/15/2025 4 17.5 102.2 ASECP001 106.0 18.2 96.4 95 D6938 Pass
Location : water storm trench, between MHC1 and MHC2, Elv/Depth :1.5 feet below finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, April 15, 2025
Reviewer Name / DateKenneth Mosman, May 02, 2025