Skip to content

Daily Field Report

Date :05/08/2025
Project No :2024C213
Client Company :WDG
Arrival Time :05/08/2025 9:00
Onsite Hours :9:00
Name of the Project :Covington Town Center PH II
Project Location :Covington, GA
Weather :sunny
Departure Time :05/08/2025 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

As requested, the site was visited by our AS Engineering and Consulting (ASEC) representative for the purpose of providing quality control inspection and testing services.  Visual observation techniques were employed to verify compliance with project drawing/specifications, applicable codes, and materials submittals. The following observations were observed on site this day.

Our ASEC representative arrived on site to observe the placement of MSE retaining walls A and B.  It was noted that a base course of No. 57 stone was placed behind the block and in the cells.  Every 2nd course geotextile reinforcement was placed followed by an 8-inch compacted lift.

No. 57 stone was utilized 1 foot behind the block and with the cells.

We appreciate the opportunity to be of service to you on this project. If you have any questions regarding this report, please feel free to contact us. We will be more than happy to discuss it with you.

Technician Signature / DateAminullah Azimi, May 8, 2025
Reviewer Name / DateKenneth Mosman, May 15, 2025