- Home
- Density Test Report Report ID: 81689
- This project is inactive from admin. Download Report
Density Test Report
Date :04/25/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :04/25/2025 9:30
Onsite Hours :06:30
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :cloudy
Departure Time :04/25/2025 16:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 04/25/2025 | 1 | 22 | 125.9 | 2025-012 SP | 105.6 | 18.9 | 97.7 | 95 | D6938 | Pass |
| Location : | Lot #21, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/25/2025 | 2 | 21 | 124.8 | 2025-012 SP | 105.6 | 18.9 | 97.6 | 95 | D6938 | Pass |
| Location : | Lot #120, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/25/2025 | 3 | 21.1 | 127.0 | 2025-012 SP | 105.6 | 18.9 | 99.3 | 95 | D6938 | Pass |
| Location : | Lot #119, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/25/2025 | 4 | 21.2 | 104.9 | 2025-012 SP | 105.6 | 18.9 | 99.3 | 95 | D6938 | Pass |
| Location : | Lot #116, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/25/2025 | 5 | 20.3 | 105.5 | 2025-012 SP | 105.6 | 18.9 | 99.9 | 95 | D6938 | Pass |
| Location : | Lot #117, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
| 04/25/2025 | 6 | 20 | 125.7 | 2025-012 SP | 105.6 | 18.9 | 99.2 | 95 | D6938 | Pass |
| Location : | Lot #118, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :85759 | |||||||||
Technician Signature / DateAminullah Azimi, April 25, 2025
Reviewer Name / DateKenneth Mosman, May 20, 2025