- Home
- Density Test Report Report ID: 81995
- Edit Download Report
Density Test Report
Date :06/06/2025
Project No :2025C146
Client Company :Davidson Homes, LLC
Arrival Time :06/06/2025 08:45
Onsite Hours :
Name of the Project :Greene Farms Subdivision
Project Location :1451 Highway 113, Cartersville, Georgia
Weather :
Departure Time :06/06/2025
ASEC Technician Name :Solomon Cherie
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 06/06/2025 | 1 | 18.5 | 104.0 | ASECP003 | 109.2 | 18.5 | 95.2 | 95 | D6938 | Pass |
| Location : | Lot #26, Elv/Depth :At finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 06/06/2025 | 2 | 16.5 | 109.2 | ASECP005 | 106.8 | 16.5 | 102.2 | 98 | D6938 | Pass |
| Location : | Lot #27, Elv/Depth :At finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 06/06/2025 | 3 | 21.8 | 100.0 | ASECP002 | 99.4 | 22.4 | 100.6 | 98 | D6938 | Pass |
| Location : | Lot #28, Elv/Depth :At finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 06/06/2025 | 4 | 13.5 | 113.2 | ASECP004 | 115.0 | 12.0 | 98.4 | 95 | D6938 | Pass |
| Location : | Lot #25, Elv/Depth :At finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 06/06/2025 | 5 | 22.5 | 97.9 | ASECP002 | 99.4 | 22.4 | 98.5 | 95 | D6938 | Pass |
| Location : | Lot #24, Elv/Depth :At finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 06/06/2025 | 6 | 18.4 | 102.1 | ASECP005 | 106.8 | 16.5 | 95.6 | 95 | D6938 | Pass |
| Location : | Lot #24, Elv/Depth :At finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 06/06/2025 | 7 | 17.4 | 105.7 | ASECP005 | 106.8 | 16.5 | 99.0 | 95 | D6938 | Pass |
| Location : | Lot #23, Elv/Depth :At finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 06/06/2025 | 8 | 10 | 130.0 | ASECP004 | 115.0 | 12.0 | 102.8 | 95 | D6938 | Pass |
| Location : | Lot #22, Elv/Depth :At finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
Technician Signature / DateSolomon Cherie, June 6, 2025
Reviewer Name / DateKenneth Mosman, June 09, 2025