Density Test Report

Date :04/04/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :04/04/2025 09:00
Onsite Hours :06:00
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Sunny
Departure Time :04/04/2025 15:00
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
04/04/2025 1 24.4 94.7 2025-011 SP 115.0 15.5 82.3 95 D2937 Fail
Location : Lot #120, Elv/Depth :10 feet below finished grade
Comment : In-situ moiture contents much higher than optimum moisture. Recommend scarification, aeration and recompaction.
04/04/2025 2 18.2 110.0 2025-011 SP 115.0 15.5 95.7 95 D2937 Pass
Location : Lot #117, Elv/Depth :10 feet below finished grade
Comment :
04/04/2025 3 18.9 104.9 2025-011 SP 115.0 15.5 91.2 95 D2937 Fail
Location : Lot #117, Elv/Depth :10 feet below finished grade
Comment : In-situ moiture contents much higher than optimum moisture. Recommend scarification, aeration and recompaction.
04/04/2025 4 15.3 111.5 2025-011 SP 115.0 15.5 97.0 95 D2937 Pass
Location : Lot #122, Elv/Depth :10 feet below finished grade
Comment :
04/04/2025 5 16.1 109.8 2025-011 SP 115.0 15.5 95.5 95 D2937 Pass
Location : Lots #33 and #34, Elv/Depth :10 feet below finished grade
Comment :
04/04/2025 6 18.3 109.9 2025-011 SP 115.0 15.5 95.6 95 D2937 Pass
Location : Lot #34, Elv/Depth :10 feet below finished grade
Comment :
04/04/2025 7 15.9 114.8 2025-011 SP 115.0 15.5 99.8 95 D2937 Pass
Location : Lot #33, Elv/Depth :10 feet below finished grade
Comment :
Technician Signature / DateSean Willett, April 4, 2025
Reviewer Name / DateKenneth Mosman, June 23, 2025