- Home
- Density Test Report Report ID: 82268
- Edit Download Report
Density Test Report
Date :06/17/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :06/17/2025 08:00
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Overcast
Departure Time :06/17/2025
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 06/17/2025 | 1 | 22.2 | 92.2 | 2025-012 SP | 105.6 | 18.9 | 87.3 | 98 | D2937 | Fail |
| Location : | Lot #39, Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
| 06/17/2025 | 2 | 20.7 | 91.2 | 2025-012 SP | 105.6 | 18.9 | 86.4 | 98 | D2937 | Fail |
| Location : | Lot #38, Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
| 06/17/2025 | 3 | 23.7 | 91.1 | 2025-012 SP | 105.6 | 18.9 | 86.3 | 98 | D2937 | Fail |
| Location : | Lot #37, Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
| 06/17/2025 | 4 | 22.9 | 93.5 | 2025-012 SP | 105.6 | 18.9 | 88.5 | 98 | D2937 | Fail |
| Location : | Lot #36 , Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
| 06/17/2025 | 5 | 24.5 | 90.9 | 2025-012 SP | 105.6 | 18.9 | 86.1 | 98 | D2937 | Fail |
| Location : | Lot #35 , Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
| 06/17/2025 | 6 | 20.5 | 95.9 | 2025-012 SP | 105.6 | 18.9 | 90.8 | 98 | D2937 | Fail |
| Location : | Lot #37, Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
| 06/17/2025 | 7 | 19.3 | 98.2 | 2025-012 SP | 105.6 | 18.9 | 93.0 | 98 | D2937 | Fail |
| Location : | Lot #33, Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
| 06/17/2025 | 8 | 26.8 | 88.6 | 2025-012 SP | 105.6 | 18.9 | 83.9 | 98 | D2937 | Fail |
| Location : | Lot #32, Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
| 06/17/2025 | 9 | 25.1 | 91.8 | 2025-012 SP | 105.6 | 18.9 | 86.9 | 98 | D2937 | Fail |
| Location : | Lot #31, Elv/Depth :at finished grade | |||||||||
| Comment : | Results given to the contractor | |||||||||
Technician Signature / DateSean Willett, June 17, 2025
Reviewer Name / DateKenneth Mosman, August 06, 2025