Skip to content

Density Test Report

Date :06/19/2025
Project No :2024C217
Client Company :Artisan
Arrival Time :06/19/2025 8:00
Onsite Hours :08:30
Name of the Project :Naturewalk - 7 Hills Amenities
Project Location :Dallas
Weather :cloudy
Departure Time :06/19/2025 16:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
06/19/2025 1 27.8 90.2 26443 101.3 19.4 89.0 95 D6938 Fail
Location : Under pit in water line , Elv/Depth :5 feet below finished grade
Comment : In-situ moisture contents well above optimum. Recommend scarifying and aerate prior to recompaction. Gauge Serial No. :85759
06/19/2025 2 28 88.6 26443 101.3 19.4 87.5 95 D6938 Fail
Location : Water line under pit , Elv/Depth :4 feet below finished grade
Comment : In-situ moisture contents well above optimum. Recommend scarifying and aerate prior to recompaction. Gauge Serial No. :85759
06/19/2025 3 18.4 100.3 26443 101.3 19.4 99.0 95 D6938 Pass
Location : Behind retaining wall, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
06/19/2025 4 17.5 99.1 26443 101.3 19.4 97.8 95 D6938 Pass
Location : Behind retaining wall #1, Elv/Depth :1 foot below finished grade
Comment : Gauge Serial No. :85759
06/19/2025 5 21.1 100.0 26443 101.3 19.4 98.7 98 D6938 Pass
Location : Behind retaining wall #1, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
06/19/2025 6 20.1 99.8 26443 101.3 19.4 98.5 98 D6938 Pass
Location : Behind retaining wall #1, Elv/Depth :at finished grade
Comment : Gauge Serial No. :85759
Technician Signature / DateAminullah Azimi, June 19, 2025
Reviewer Name / DateKenneth Mosman, July 17, 2025