Skip to content

Density Test Report

Date :07/18/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :07/18/2025 08:30
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Overcast
Departure Time :07/18/2025
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
07/18/2025 1 18.1 101.9 2025-012 SP 105.6 18.9 96.5 95 D2937 Pass
Location : Lot #72, Elv/Depth :775
Comment :
07/18/2025 2 16.9 102.9 2025-012 SP 105.6 18.9 97.4 95 D2937 Pass
Location : Lot #73, Elv/Depth :775
Comment :
07/18/2025 3 16.3 105.6 2025-012 SP 105.6 18.9 100.0 95 D2937 Pass
Location : Lot #74, Elv/Depth :775
Comment :
07/18/2025 4 17.3 101.1 2025-012 SP 105.6 18.9 95.7 95 D2937 Pass
Location : Lot #75-76, Elv/Depth :775
Comment :
07/18/2025 5 13.6 101.2 2025-012 SP 105.6 18.9 95.8 98 D2937 Fail
Location : Lot #166, Elv/Depth :at finished grade
Comment :
07/18/2025 6 15.7 96.2 2025-012 SP 105.6 18.9 91.1 98 D2937 Fail
Location : Lot #167, Elv/Depth :at finished grade
Comment : In-situ moisture content well BELOW optimum moisture. Add some moisture and recompact.
Technician Signature / DateSean Willett, July 18, 2025
Reviewer Name / DateKenneth Mosman, August 08, 2025