- Home
- Density Test Report Report ID: 83728
- Edit Download Report
Density Test Report
Date :08/01/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :08/01/2025 08:30
Onsite Hours :
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Sunny - wet site
Departure Time :08/01/2025
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 08/01/2025 | 1 | 21.9 | 86.7 | 2025-025 SP | 104.5 | 13.2 | 83.0 | 95 | D2937 | Fail |
| Location : | Lot #58, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | In-situ moisture contents well above optimum moisture content. | |||||||||
| 08/01/2025 | 2 | 29.4 | 84.3 | 2025-012 SP | 105.6 | 18.9 | 79.8 | 95 | D2937 | Fail |
| Location : | Lot #55, Elv/Depth :-7ft | |||||||||
| Comment : | In-situ moisture contents well above optimum moisture content. | |||||||||
Technician Signature / DateSean Willett, August 1, 2025
Reviewer Name / DateKenneth Mosman, August 11, 2025