- Home
- Density Test Report Report ID: 84365
- Edit Download Report
Density Test Report
Date :07/30/2025
Project No :2025C146
Client Company :Davidson Homes, LLC
Arrival Time :07/30/2025 9:00
Onsite Hours :08:00
Name of the Project :Greene Farms Subdivision
Project Location :1451 Highway 113, Cartersville, Georgia
Weather :sunny
Departure Time :07/30/2025 17:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 07/30/2025 | 1 | 25.3 | 96.9 | ASECP002 | 99.4 | 22.4 | 97.5 | 95 | D6938 | Pass |
| Location : | Lot #36, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 2 | 23.1 | 97.9 | ASECP002 | 99.4 | 22.4 | 98.5 | 95 | D6938 | Pass |
| Location : | Lot #95, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 3 | 23.4 | 96.8 | ASECP002 | 99.4 | 22.4 | 97.4 | 95 | D6938 | Pass |
| Location : | Lot #40, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 4 | 21.7 | 97.1 | ASECP002 | 99.4 | 22.4 | 97.7 | 95 | D6938 | Pass |
| Location : | Lot #41, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 5 | 23.2 | 97.0 | ASECP002 | 99.4 | 22.4 | 97.6 | 95 | D6938 | Pass |
| Location : | Lot #42, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 6 | 22.1 | 96.9 | ASECP002 | 99.4 | 22.4 | 97.5 | 95 | D6938 | Pass |
| Location : | Lot #43, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 7 | 24.3 | 96.8 | ASECP002 | 99.4 | 22.4 | 97.4 | 95 | D6938 | Pass |
| Location : | Lot #44, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 08/30/2025 | 8 | 21.7 | 95.9 | ASECP002 | 99.4 | 22.4 | 96.5 | 95 | D6938 | Pass |
| Location : | Lot #45, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 9 | 20.1 | 97.2 | ASECP002 | 99.4 | 22.4 | 97.8 | 95 | D6938 | Pass |
| Location : | Lot #46, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 10 | 20.5 | 97.3 | ASECP002 | 99.4 | 22.4 | 97.9 | 95 | D6938 | Pass |
| Location : | Lot #47, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 11 | 21.5 | 96.1 | ASECP002 | 99.4 | 22.4 | 96.7 | 95 | D6938 | Pass |
| Location : | Lot #17, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 12 | 21.2 | 96.3 | ASECP002 | 99.4 | 22.4 | 96.9 | 95 | D6938 | Pass |
| Location : | Lot #18, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 13 | 23.1 | 95.9 | ASECP002 | 99.4 | 22.4 | 96.5 | 95 | D6938 | Pass |
| Location : | Lot #19, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 14 | 22.1 | 96.5 | ASECP002 | 99.4 | 22.4 | 97.1 | 95 | D6938 | Pass |
| Location : | Lot #20, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
| 07/30/2025 | 15 | 23.1 | 95.9 | ASECP002 | 99.4 | 22.4 | 96.5 | 95 | D6938 | Pass |
| Location : | Lot #21, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :29588 | |||||||||
Technician Signature / DateAminullah Azimi, July 30, 2025
Reviewer Name / DateKenneth Mosman, August 24, 2025