Skip to content

Density Test Report

Date :07/31/2025
Project No :2025C146
Client Company :Davidson Homes, LLC
Arrival Time :07/31/2025 9:00
Onsite Hours :08:30
Name of the Project :Greene Farms Subdivision
Project Location :1451 Highway 113, Cartersville, Georgia
Weather :sunny
Departure Time :07/31/2025 17:30
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
07/31/2025 1 30 83.4 ASECP002 99.4 22.4 83.9 95 D6938 Fail
Location : Between MHA11 and MHA12, Elv/Depth :3 feet below finished grade
Comment : This test failed due to high moisture contents. Recommended to scarify, aerate and recompact. Gauge Serial No. :29588
07/31/2025 2 10.9 110.9 ASECP004 115.0 12.0 96.4 95 D6938 Pass
Location : Lot #86, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
07/31/2025 3 11.3 112.9 ASECP004 115.0 12.0 98.2 95 D6938 Pass
Location : Lot #85, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
07/31/2025 4 11.4 111.4 ASECP004 115.0 12.0 96.9 95 D6938 Pass
Location : Lot #84, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
07/31/2025 5 14.7 103.8 ASECP005 106.8 16.5 97.2 95 D6938 Pass
Location : Lot #83, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
07/31/2025 6 12.5 123.5 ASECP004 115.0 12.0 95.5 95 D6938 Pass
Location : Lot #82, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
07/31/2025 7 12.3 109.4 ASECP004 115.0 12.0 95.1 95 D6938 Pass
Location : Lot #81, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :29588
Technician Signature / DateAminullah Azimi, July 31, 2025
Reviewer Name / DateKenneth Mosman, August 24, 2025