Density Test Report

Date :08/07/2025
Project No :2023C180
Client Company :Artisan Communities
Arrival Time :08/07/2025 9:00
Onsite Hours :9:00
Name of the Project :Lakeside Sub., Lovers Lane > Retaining Wall
Project Location :Calhoun
Weather :sunny
Departure Time :08/07/2025 18:00
ASEC Technician Name :Aminullah Azimi

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
08/07/2025 1 25.6 110.2 P-02 91.6 25.6 95.7 95 D6938 Pass
Location : Station 1+10, Elv/Depth :3.5 feet below finished grade
Comment : Gauge Serial No. :29588
08/07/2025 2 24.9 87.5 P-02 91.6 25.6 95.5 95 D6938 Pass
Location : Station 1+20, Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :29588
08/07/2025 3 25.7 88.0 P-02 91.6 25.6 96.1 95 D6938 Pass
Location : station 0+55, Elv/Depth :1.5 feet below finished grade
Comment : Gauge Serial No. :29588
08/07/2025 4 25.1 87.3 P-02 91.6 25.6 95.3 95 D6938 Pass
Location : station 1+20, Elv/Depth :1.5 feet below finished grade
Comment : Gauge Serial No. :29588
Technician Signature / DateAminullah Azimi, August 7, 2025
Reviewer Name / DateKenneth Mosman, August 24, 2025