- Home
- Density Test Report Report ID: 84694
- Edit Download Report
Density Test Report
Date :08/22/2025
Project No :2025C215
Client Company :Artisan
Arrival Time :08/22/2025 9:00
Onsite Hours :08:00
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :sunny
Departure Time :08/22/2025 17:00
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 08/22/2025 | 1 | 19.1 | 96.6 | 2025-031 SP | 101.0 | 20.7 | 95.6 | 95 | D6938 | Pass |
| Location : | Sewer trench 128 feet to the east of MH8, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 2 | 18.2 | 97.3 | 2025-031 SP | 101.0 | 20.7 | 96.3 | 95 | D6938 | Pass |
| Location : | Sewer trench 156 feet to the west of MH6, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 3 | 21.3 | 91.7 | 2025-032 SP | 94.9 | 25.0 | 96.6 | 95 | D6938 | Pass |
| Location : | Sewer trench 87 feet to the west of MH6, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 4 | 18.7 | 116.2 | 2025-031 SP | 101.0 | 20.7 | 96.9 | 95 | D6938 | Pass |
| Location : | Sewer trench 107 feet to the east of MH8, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 5 | 15 | 113.0 | 2025-031 SP | 101.0 | 20.7 | 97.3 | 95 | D6938 | Pass |
| Location : | Sewer trench 178 feet to the west from MH6, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 6 | 19.1 | 114.9 | 2025-031 SP | 101.0 | 20.7 | 95.5 | 95 | D6938 | Pass |
| Location : | Sewer trench 112 feet to the west of MH6, Elv/Depth :3.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 7 | 19.8 | 115.1 | 2025-031 SP | 101.0 | 20.7 | 95.1 | 95 | D6938 | Pass |
| Location : | Sewer trench 63 feet to the west of MH6, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 8 | 13.2 | 98.5 | 2025-031 SP | 101.0 | 20.7 | 97.5 | 95 | D6938 | Pass |
| Location : | Lot #14, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 9 | 11.6 | 98.7 | 2025-031 SP | 101.0 | 20.7 | 97.7 | 95 | D6938 | Pass |
| Location : | Lot #15, Elv/Depth :1 foot below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 10 | 14.2 | 98.3 | 2025-031 SP | 101.0 | 20.7 | 97.3 | 95 | D6938 | Pass |
| Location : | Sewer trench 82 feet to the west from MH6, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
| 08/22/2025 | 11 | 18.2 | 98.1 | 2025-031 SP | 101.0 | 20.7 | 97.1 | 95 | D6938 | Pass |
| Location : | Sewer trench 129 feet to the east of MH8, Elv/Depth :1,5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :30942 | |||||||||
Technician Signature / DateAminullah Azimi, August 22, 2025
Reviewer Name / DateKenneth Mosman, September 12, 2025