Density Test Report
Date :09/02/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :09/02/2025 08:00
Onsite Hours :07:30
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :Sunny/overcast
Departure Time :09/02/2025 15:30
ASEC Technician Name :Sean Willett
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/02/2025 | 1 | 14.1 | 117.9 | 2025-008 SP | 115.7 | 14.7 | 101.9 | 98 | D6938 | Pass |
| Location : | Lot #172, Elv/Depth :792 | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 09/02/2025 | 2 | 17.7 | 102.5 | 2025-025 SP | 104.5 | 13.2 | 98.1 | 98 | D6938 | Pass |
| Location : | Lot #182, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :77-19952 | |||||||||
| 09/02/2025 | 3 | 14.2 | 94.0 | 2025-012 SP | 105.6 | 18.9 | 89.0 | 98 | D6938 | Fail |
| Location : | Lot #181, Elv/Depth :at finished grade | |||||||||
| Comment : | Recommend recompaction of this area. Contractor agreed. | Gauge Serial No. :77-19952 | ||||||||
| 09/02/2025 | 4 | 15.3 | 96.2 | 2025-012 SP | 105.6 | 18.9 | 91.1 | 98 | D6938 | Fail |
| Location : | Lot #181, Elv/Depth :at finished grade | |||||||||
| Comment : | Recommend recompaction of this area. Contractor agreed. | Gauge Serial No. :77-19952 | ||||||||
| 09/02/2025 | 5 | 25.1 | 117.8 | 2025-012 SP | 105.6 | 18.9 | 89.2 | 98 | D6938 | Fail |
| Location : | Lot #180, Elv/Depth :at finished grade | |||||||||
| Comment : | High in-situ moisture content. Recommend scarify, aerate and recompaction of this area. Contractor agreed. | Gauge Serial No. :77-19952 | ||||||||
Technician Signature / DateSean Willett, September 2, 2025
Reviewer Name / DateKenneth Mosman, September 17, 2025