Skip to content

Density Test Report

Date :09/05/2025
Project No :2025C160
Client Company :Artisan
Arrival Time :09/05/2025 08:00
Onsite Hours :01:30
Name of the Project :Rockmart Township - 115 Felton Drive
Project Location :Rockmart
Weather :sunny
Departure Time :09/05/2025 09:30
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
09/05/2025 1 14 103.2 2025-025 SP 104.5 13.2 98.8 98 D6938 Pass
Location : Lot #59, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
09/05/2025 2 18.8 104.0 2025-012 SP 105.6 18.9 98.5 98 D6938 Pass
Location : Lot #58, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
09/05/2025 3 19.8 103.5 2025-012 SP 105.6 18.9 98.0 98 D6938 Fail
Location : Lot #57, Elv/Depth :at finished grade
Comment : Gauge Serial No. :77-19952
09/05/2025 4 23.2 88.4 2025-012 SP 105.6 18.9 83.7 98 D6938 Fail
Location : Lot #170, Elv/Depth :at finished grade
Comment : In-situ moisture content much higher than optimum. Gauge Serial No. :77-19952
09/05/2025 5 17.3 91.8 2025-012 SP 105.6 18.9 86.9 98 D6938 Fail
Location : Lot #170, Elv/Depth :at finished grade
Comment : Recompaction required. Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, September 5, 2025
Reviewer Name / DateKenneth Mosman, October 15, 2025