- Home
- Density Test Report Report ID: 86318
- Edit Download Report
Density Test Report
Date :09/24/2025
Project No :2025C224
Client Company :C. W. MATTHEWS CONTRACTING CO., INC.
Arrival Time :09/24/2025 7:00
Onsite Hours :10:30
Name of the Project :PDK Airport - RUNWAY 3R-21L KEEL REPLACEMENT
Project Location :PDK AIRPORT, DEKALB County, GA
Weather :sunny
Departure Time :09/24/2025 17:30
ASEC Technician Name :Aminullah Azimi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 09/24/2025 | 1 | 9.5 | 125.4 | 2025-037-MP | 132.9 | 8.2 | 94.4 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 09/24/2025 | 2 | 9 | 125.2 | 2025-037-MP | 132.9 | 8.2 | 94.2 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 09/24/2025 | 3 | 7.5 | 127.2 | 2025-037-MP | 132.9 | 8.2 | 95.7 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 09/24/2025 | 4 | 9.2 | 125.5 | 2025-037-MP | 132.9 | 8.2 | 94.4 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 09/24/2025 | 5 | 8.5 | 126.2 | 2025-037-MP | 132.9 | 8.2 | 95.0 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Needs a GAB proctor for results | Gauge Serial No. :38069 | ||||||||
| 09/24/2025 | 6 | 9.2 | 125.4 | 2025-037-MP | 132.9 | 8.2 | 94.4 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 09/24/2025 | 7 | 9.2 | 125.2 | 2025-037-MP | 132.9 | 8.2 | 94.2 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 09/24/2025 | 8 | 9.2 | 125.3 | 2025-037-MP | 132.9 | 8.2 | 94.3 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 09/24/2025 | 9 | 9.1 | 125.1 | 2025-037-MP | 132.9 | 8.2 | 94.1 | 100 | D6938 | Fail |
| Location : | Taxiway A, Elv/Depth :at finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
Technician Signature / DateAminullah Azimi, September 24, 2025
Reviewer Name / DateKenneth Mosman, October 10, 2025