Skip to content

Density Test Report

Date :10/09/2025
Project No :2025C215
Client Company :Artisan
Arrival Time :10/09/2025 09:00
Onsite Hours :03:30
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :Cloudy
Departure Time :10/09/2025 12:30
ASEC Technician Name :Austin Coleman

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/09/2025 1 13.8 100.8 2025-031 SP 101.0 20.7 99.8 98 D6938 Pass
Location : Lot #7 (retest), Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/09/2025 2 13.0 102.0 2025-033 SP 104.0 16.2 98.1 98 D6938 Pass
Location : Lot #8, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
10/09/2025 3 13.2 102.1 2025-033 SP 104.0 16.2 98.2 98 D6938 Pass
Location : Lot #9, Elv/Depth :at finished grade
Comment : Gauge Serial No. :30942
Technician Signature / DateAustin Coleman, October 9, 2025
Reviewer Name / DateKenneth Mosman, October 17, 2025