Skip to content

Density Test Report

Date :10/13/2025
Project No :2025C224
Client Company :C. W. MATTHEWS CONTRACTING CO., INC.
Arrival Time :10/13/2025
Onsite Hours :
Name of the Project :PDK Airport - RUNWAY 3R-21L KEEL REPLACEMENT
Project Location :PDK AIRPORT, DEKALB County, GA
Weather :sunny
Departure Time :10/13/2025
ASEC Technician Name :Russell Hendrix

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
10/13/2025 1 7.8 119.4 2025-037-MP 132.9 8.2 89.8 100 D6938 Fail
Location : 1045, Elv/Depth :
Comment : Using Nova's proctor also failed compaction. Recommend recompaction and retesting. Gauge Serial No. :38069
10/13/2025 2 8.2 118.2 2025-037-MP 132.9 8.2 88.9 100 D6938 Fail
Location : 1040, Elv/Depth :
Comment : Using Nova's proctor also failed compaction. Recommend recompaction and retesting. Gauge Serial No. :38069
10/13/2025 3 ( retest) 11 113.5 2025-037-MP 132.9 8.2 85.4 100 D6938 Fail
Location : 1030, Elv/Depth :
Comment : Using Nova's proctor also failed compaction. Recommend recompaction and retesting. Gauge Serial No. :38069
10/13/2025 4 restest 7.9 117.7 2025-037-MP 132.9 8.2 88.6 100 D6938 Fail
Location : 1020, Elv/Depth :
Comment : Using Nova's proctor also failed compaction. Recommend recompaction and retesting. Gauge Serial No. :38069
10/13/2025 5 7.5 118.3 2025-037-MP 132.9 8.2 89.0 100 D6938 Fail
Location : 1015, Elv/Depth :
Comment : Using Nova's proctor also failed compaction. Recommend recompaction and retesting. Gauge Serial No. :38069
10/13/2025 6 9.2 117.6 2025-037-MP 132.9 8.2 88.5 100 D6938 Fail
Location : 1010, Elv/Depth :
Comment : Using Nova's proctor also failed compaction. Recommend recompaction and retesting. Gauge Serial No. :38069
10/13/2025 7 8.6 117.5 2025-037-MP 132.9 8.2 88.4 100 D6938 Fail
Location : 1005, Elv/Depth :
Comment : Using Nova's proctor also failed compaction. Recommend recompaction and retesting. Gauge Serial No. :30869
10/13/2025 8 10.2 118.4 2025-037-MP 132.9 8.2 89.1 100 D6938 Fail
Location : end of completed section, Elv/Depth :
Comment : Using Nova's proctor also failed compaction. Recommend recompaction and retesting. Gauge Serial No. :38069
Technician Signature / DateRussell Hendrix, October 13, 2025
Reviewer Name / DateKenneth Mosman, October 16, 2025