Skip to content

Daily Field Report

Date :11/20/2025
Project No :2025C269
Client Company :Lewis Contracting
Arrival Time :11/20/2025 14:00
Onsite Hours :03:00
Name of the Project :Mixed-Use @ Main St. & First Ave.
Project Location :Lilburn
Weather :Sunny
Departure Time :11/20/2025 17:00
ASEC Technician Name :Clyde Smith

Observations/Finding

As requested, the site was visited by our AS Engineering and Consulting (ASEC) representative for the purpose of providing quality control inspection and testing services.  Visual observation techniques were employed to verify compliance with project drawing/specifications, applicable codes, and materials submittals. The following observations were observed on site this day.

On the above date our representative was on site to obtain proctor samples. Three bag samples were obtained and transported to our lab to perform a moisture density relationship (proctor). Proctor sample #1 was obtained from the center of the site/west side from an excavation to a depth of -6′ and sample #2 and #3 was obtained from the southwest corner of the site from the underground detention area. Sample #2 was mixed from 0′ to -6′ and #3 was obtained from -6′ to -8′ and in-situ moisture contents appear to be above optimum.

We appreciate the opportunity to be of service to you on this project. If you have any questions regarding this report, please feel free to contact us. We will be more than happy to discuss it with you.

Obtaining proctor samples #2 and 3 at SW corner of site

Obtaining proctor sample #1 at west side of site

Technician Signature / DateClyde Smith, November 20, 2025
Reviewer Name / DateKenneth Mosman, November 25, 2025