- Home
- Density Test Report Report ID: 88177
- Edit Download Report
Density Test Report
Date :11/21/2025
Project No :2025C244
Client Company :McCallan Group
Arrival Time :11/21/2025 11:30
Onsite Hours :01:30
Name of the Project :Cassville Rd tract, proposed Burrito Wrap
Project Location :Cartersville
Weather :sunny
Departure Time :11/21/2025 13:00
ASEC Technician Name :Samara Simha Reddy Kandi
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 11/21/2025 | 1 | 16.1 | 104.1 | 2025-051 | 106.4 | 19.3 | 97.8 | 95 | D6938 | Pass |
| Location : | Building #14, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 11/21/2025 | 2 | 12.8 | 100.1 | 2025-050 | 103.5 | 21.4 | 96.7 | 95 | D6938 | Pass |
| Location : | Building #14, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | In-situ moisture content much lower than optimum moisture content. | Gauge Serial No. :38069 | ||||||||
| 11/21/2025 | 3 | 16.1 | 97.2 | 2025-051 | 106.4 | 19.3 | 91.4 | 95 | D6938 | Fail |
| Location : | Building #14, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Recompaction required. | Gauge Serial No. :38069 | ||||||||
| 11/21/2025 | 4 | 13.8 | 95.9 | 2025-051 | 106.4 | 19.3 | 90.1 | 95 | D6938 | Fail |
| Location : | Building #14, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Recompaction required. | Gauge Serial No. :38069 | ||||||||
| 11/21/2025 | 5 | 13.6 | 96.4 | 2025-051 | 106.4 | 19.3 | 90.6 | 95 | D6938 | Fail |
| Location : | Building #14, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Recompaction required. | Gauge Serial No. :38069 | ||||||||
| 11/21/2025 | 6 | 15.2 | 104.7 | 2025-051 | 106.4 | 19.3 | 98.4 | 95 | D6938 | Pass |
| Location : | Building #14 (retest), Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
| 11/21/2025 | 7 | 16 | 102.5 | 2025-051 | 106.4 | 19.3 | 96.3 | 95 | D6938 | Pass |
| Location : | Building #14 (retest), Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :38069 | |||||||||
Technician Signature / DateSamara Simha Reddy Kandi, November 21, 2025
Reviewer Name / DateKenneth Mosman, November 25, 2025