Skip to content

Density Test Report

Date :12/29/2025
Project No :2025C260
Client Company :Artisan
Arrival Time :12/29/2025 10:00
Onsite Hours :06:00
Name of the Project :NW (PHASE 2) Parkway Extension
Project Location :Dallas
Weather :cloudy
Departure Time :12/29/2025 16:00
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
12/29/2025 1 12.4 103.7 2025-035 SP 107.8 13.0 96.2 95 D6938 Pass
Location : Cul de sac basement lots, Elv/Depth :873
Comment : Gauge Serial No. :91643
12/29/2025 2 11.9 104.9 2025-035 SP 107.8 13.0 97.3 95 D6938 Pass
Location : Cul de sac basement lots, Elv/Depth :872
Comment : Gauge Serial No. :91643
12/29/2025 3 11.2 103.3 2025-035 SP 107.8 13.0 95.8 95 D6938 Pass
Location : Cul de sac , Elv/Depth :871
Comment : Gauge Serial No. :91643
12/29/2025 4 12.7 104.4 2025-035 SP 107.8 13.0 96.8 95 D6938 Pass
Location : Cul de sac basement lots, Elv/Depth :869
Comment : Gauge Serial No. :91643
12/29/2025 5 10.8 104.5 2025-035 SP 107.8 13.0 96.9 95 D6938 Pass
Location : Cul de sac basement lots, Elv/Depth :870
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, December 29, 2025
Reviewer Name / DateKenneth Mosman, January 30, 2026