Skip to content

Density Test Report

Date :01/19/2026
Project No :2025C215
Client Company :Artisan
Arrival Time :01/19/2026 09:00
Onsite Hours :08:30
Name of the Project :NW Unit 4 Parkway Ext. Phase 1
Project Location :Dallas
Weather :sunny cold
Departure Time :01/19/2026 17:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
01/19/2026 1 14.7 102.4 2025-033 SP 104.0 16.2 98.5 95 D6938 Pass
Location : Backfill for 8" PVC sanitary sewer line , Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :91643
01/19/2026 2 14.2 103.6 2025-035 SP 107.8 13.0 96.1 95 D6938 Pass
Location : Backfill for 8" PVC sanitary sewer line , Elv/Depth :2.5 feet below finished grade
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, January 19, 2026
Reviewer Name / DateKenneth Mosman, February 04, 2026