Density Test Report
Date :02/02/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :02/02/2026 08:30
Onsite Hours :9:00
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :Sunny
Departure Time :02/02/2026 17:30
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 02/02/2026 | 1 | 12.4 | 100.9 | 2025-033 SP | 104.0 | 16.2 | 97.0 | 95 | D6938 | Pass |
| Location : | Building Lot #32, Elv/Depth :10 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 2 | 14.0 | 99.0 | 2025-033 SP | 104.0 | 16.2 | 95.2 | 95 | D6938 | Pass |
| Location : | Building lot #32, Elv/Depth :6.5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 3 | 18.9 | 107.7 | 2025-036 SP | 107.0 | 18.5 | 100.7 | 95 | D6938 | Pass |
| Location : | Building lot# 33, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 4 | 10.3 | 104.2 | 2025-035 SP | 107.8 | 13.0 | 96.7 | 95 | D6938 | Pass |
| Location : | Building lot# 33, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 5 | 14.0 | 101.7 | 2025-033 SP | 104.0 | 16.2 | 97.8 | 95 | D6938 | Pass |
| Location : | Building lot 34, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 6 | 14.4 | 102.2 | 2025-033 SP | 104.0 | 16.2 | 98.3 | 95 | D6938 | Pass |
| Location : | Building lot3 34, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 7 | 16.2 | 97.2 | Field proctor #6 | 98.0 | 17.2 | 99.2 | D6938 | Pass | |
| Location : | Building lot3 57, Elv/Depth :862 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 8 | 13.8 | 98.2 | Field proctor #6 | 98.0 | 17.2 | 100.2 | 95 | D6938 | Pass |
| Location : | Building lot#57, Elv/Depth :865 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 9 | 16.9 | 97.6 | Field proctor #6 | 98.0 | 17.2 | 99.6 | 95 | D6938 | Pass |
| Location : | Building lot# 58, Elv/Depth :864 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 10 | 16.4 | 97.3 | Field proctor #6 | 98.0 | 17.2 | 99.3 | 95 | D6938 | Pass |
| Location : | Building lot #59, Elv/Depth :866 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 02/02/2026 | 11 | 15.9 | 97.3 | Field proctor #6 | 98.0 | 17.2 | 99.3 | 95 | D6938 | Pass |
| Location : | Building lot#60, Elv/Depth :867 | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, February 2, 2026
Reviewer Name / DateKenneth Mosman, February 16, 2026