Skip to content

Density Test Report

Date :02/03/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :02/03/2026 08:00
Onsite Hours :9:30
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :cloudy
Departure Time :02/03/2026 17:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/03/2026 1 15.2 102.7 2025-036 SP 107.0 18.5 96.0 95 D6938 Pass
Location : Building Lots #38 thru 36, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 2 16.2 102.6 2025-036 SP 107.0 18.5 95.9 95 D6938 Pass
Location : Building Lots #38 thru 36, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 3 16.9 103.0 2025-036 SP 107.0 18.5 96.3 95 D6938 Pass
Location : Building Lots #38 thru 36, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 4 17.1 105.4 2025-036 SP 107.0 18.5 98.5 98 D6938 Pass
Location : Building Lots #38 thru 36, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 5 15.9 106.4 2025-036 SP 107.0 18.5 99.4 98 D6938 Pass
Location : Building Lots #38 thru 36, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 6 17.2 107.1 2025-036 SP 107.0 18.5 100.1 D6938 Pass
Location : Building Lots #38 thru 36, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 7 13.7 102.6 2025-033 SP 104.0 16.2 98.7 95 D6938 Pass
Location : Building Lots #32 thru 34 , Elv/Depth :3 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 8 14.2 102.7 2025-033 SP 104.0 16.2 98.8 98 D6938 Pass
Location : Building Lots #32 thru 34, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 9 14.6 102.7 2025-033 SP 104.0 16.2 98.8 D6938 Pass
Location : Building Lots #32 thru 34, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :91643
02/03/2026 10 16.6 97.7 Field proctor #6 98.0 17.2 99.7 95 D6938 Pass
Location : Building Lot #56, Elv/Depth : 866
Comment : Gauge Serial No. :91643
02/03/2026 11 15.1 99.0 Field proctor #6 98.0 17.2 101.0 95 D6938 Pass
Location : Building Lot #56, Elv/Depth :867
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, February 3, 2026
Reviewer Name / DateKenneth Mosman, February 16, 2026