Density Test Report

Date :02/18/2026
Project No :2025C211
Client Company :Pulte
Arrival Time :02/18/2026 07:30
Onsite Hours :06:00
Name of the Project :Haley's Bluff - Philadelphia Rd.
Project Location :Jasper
Weather :Sunny
Departure Time :02/18/2026 13:30
ASEC Technician Name :Sean Willett

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
02/18/2026 1 17.5 97.7 FP 2 100.0 18.5 97.7 95 D6938 Pass
Location : Retaining wall #2, Elv/Depth :9 baskets
Comment : Gauge Serial No. :77-19952
02/18/2026 2 19.5 99.3 FP 2 100.0 18.5 99.3 95 D6938 Pass
Location : Retaining wall #2, Elv/Depth :9 baskets
Comment : Gauge Serial No. :77-19952
Technician Signature / DateSean Willett, February 18, 2026
Reviewer Name / DateKenneth Mosman, February 26, 2026