- Home
- Density Test Report Report ID: 90938
- Edit Download Report
Density Test Report
Date :03/02/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :03/02/2026 08:00
Onsite Hours :08:00
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :cloudy
Departure Time :03/02/2026 16:00
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 03/02/2026 | 1 | 14.7 | 101.8 | 2025-033 SP | 104.0 | 16.2 | 97.9 | 95 | D6938 | Pass |
| Location : | Backfill of 8" ductile iron SS line between #4 and 2, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/02/2026 | 2 | 15.5 | 102.9 | 2025-035 SP | 107.8 | 13.0 | 95.5 | 95 | D6938 | Pass |
| Location : | Backfill of 8" ductile iron SS line between #4 and 2, Elv/Depth :4 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/02/2026 | 3 | 12.8 | 119.2 | 2025-035 SP | 107.8 | 13.0 | 98.1 | 98 | D6938 | Pass |
| Location : | Backfill of 8" ductile iron SS line between #4 and 2, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/02/2026 | 4 | 13.0 | 105.7 | 2025-035 SP | 107.8 | 13.0 | 98.1 | 98 | D6938 | Pass |
| Location : | Backfill of 8" ductile iron SS line between #4 and 2, Elv/Depth :2 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, March 2, 2026
Reviewer Name / DateKenneth Mosman, March 11, 2026