- Density Test Report Report ID: 91265
- Edit Download Report
Density Test Report
Date :03/13/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :03/13/2026 08:00
Onsite Hours :08:00
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :sunny
Departure Time :03/13/2026 16:00
ASEC Technician Name :Clyde Smith
Observations/Finding
| Test Date | Test Number | Moisture Content (%) | Dry Density (pcf) | Proctor Number | Max. Dry Density (pcf) | Optimum Moisture (%) | Compaction (%) | Specified Compaction (%) | ASTM Test Method | Pass/Fail |
|---|---|---|---|---|---|---|---|---|---|---|
| 03/13/2026 | 1 | 15.8 | 96.9 | Field proctor #6 | 98.0 | 17.2 | 98.9 | 95 | D6938 | Pass |
| Location : | Backfill at SS trench between B8 and B9, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/13/2026 | 2 | 14.9 | 110.2 | Field proctor #6 | 98.0 | 17.2 | 97.9 | 95 | D6938 | Pass |
| Location : | Backfill at SS trench between B8 and B9, Elv/Depth :5 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
| 03/13/2026 | 3 | 15.1 | 96.3 | Field proctor #6 | 98.0 | 17.2 | 98.3 | 95 | D6938 | Pass |
| Location : | Backfill at SS trench between B8 and B9, Elv/Depth :3 feet below finished grade | |||||||||
| Comment : | Gauge Serial No. :91643 | |||||||||
Technician Signature / DateClyde Smith, March 13, 2026
Reviewer Name / DateKenneth Mosman, March 19, 2026