Skip to content

Density Test Report

Date :03/18/2026
Project No :2026C103
Client Company :Artisan
Arrival Time :03/18/2026 08:00
Onsite Hours :9:30
Name of the Project :NW PH 2, UNIT 4
Project Location :Dallas
Weather :sunny
Departure Time :03/18/2026 17:30
ASEC Technician Name :Clyde Smith

Observations/Finding

Test Date Test Number Moisture Content (%) Dry Density (pcf) Proctor Number Max. Dry Density (pcf) Optimum Moisture (%) Compaction (%) Specified Compaction (%) ASTM Test Method Pass/Fail
03/18/2026 1 15.7 95.6 Field proctor #6 98.0 17.2 97.6 95 D6938 Pass
Location : 8" sanitary sewer trench between B9 and B11, Elv/Depth :6 feet below finished grade
Comment : Gauge Serial No. :91643
03/18/2026 2 15.9 95.1 Field proctor #6 98.0 17.2 97.0 95 D6938 Pass
Location : 8" sanitary sewer trench between B9 and B11, Elv/Depth :6 feet below finished grade
Comment : Gauge Serial No. :91643
03/18/2026 3 13.7 101.4 2025-033 SP 104.0 16.2 97.5 95 D6938 Pass
Location : 8"sanitary sewer trench between B9 and B11, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :91643
03/18/2026 4 15.8 96.2 Field proctor #6 98.0 17.2 98.2 95 D6938 Pass
Location : 8" sanitary sewer trench between B9 and B11, Elv/Depth :4 feet below finished grade
Comment : Gauge Serial No. :91643
03/18/2026 5 14.6 101.6 2025-033 SP 104.0 16.2 97.7 98 D6938 Fail
Location : 8" sanitary sewer trench between B9 and B11, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :91643
03/18/2026 6 13.6 96.7 Field proctor #6 98.0 17.2 98.7 98 D6938 Pass
Location : 8" sanitary sewer trench between B9 and B11, Elv/Depth :2 feet below finished grade
Comment : Gauge Serial No. :91643
Technician Signature / DateClyde Smith, March 18, 2026
Reviewer Name / DateKenneth Mosman, March 19, 2026